What is the purpose of an MI RTD cable over thermocouple cable?
RTD Cable in contrast to thermocouple (TC) cable are limited to a maximum temperature of 500°C. TC Cable can go up to 1500°C. RTDs however are superior to thermocouples in that their readings are more accurate and they produce more stable readings over a longer period of time.
K Type Thermocouple MI Cable With Stainless Steel Sheath
Quick Details:
Name:4.8mm Single Core Mineral Insulated Thermocouple Cable SS316 Type K
Conductor material: NiCr-NiAl
Insulator: 99.6% high purity MgO
Dia(mm): 0.3mm to 12.7mm
Core: single and double
Type for Sheath Wire Type K
Product Name | Code | Type | Shaeth Material | Outside Dia. | Temperature |
NiCr-NiSi /NiCr-NiAl | KK | K | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
SS310 Inconel600 | 0.5-1.0 | 500 | |||
1.5-3.2 | 800 | ||||
4.0-6.4 | 900 | ||||
8.0-12.7 | 1000 | ||||
NiCrSi-NiSi | NK | N | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
SS310 Inconel600 | 0.5-1.0 | 500 | |||
1.5-3.2 | 800 | ||||
4.0-6.4 | 900 | ||||
8.0-12.7 | 1000 | ||||
NiCr-Konstantan | EK | E | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
Fe-Konstantan | JK | J | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
Cu-Konstantan | TK | T | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
RhPt10-Ph | SK | S | Inconel600 | 6.0-12.7 | 1100 |
Accuracy for Sheath Wire
Type | Class I | Class II | ||
Accuracy | Temp.Range | Accuracy | Temp.Range | |
K | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-1000℃ | ±0.75% | 375℃-1000℃ | |
N | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-1000℃ | ±0.75% | 375℃-1000℃ | |
E | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-800℃ | ±0.75% | 375℃-800℃ | |
J | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-800℃ | ±0.75% | 375℃-800℃ | |
T | ±0.5℃ | -40~125℃ | ±1.0℃ | -40~125℃ |
±0.4% | 125℃-350℃ | ±0.75% | 125℃-350℃ | |
S | 0-1100℃ | ±1.0℃ | 0-1100℃ | ±1.5℃ |
Product Pictures
Company Information:
A. Main Products
B. Invention Patent :Manufacturing method of sheath thermocouple cable
Usage:Raw material of sheath thermocouple
C. Warehouse
We have great amount mi cable in stock. We expecting your visiting.
FAQ:
1. Accurate quotation. |
2. Confirm the price, trade term, lead time, payment term etc. |
3. LEADKIN sales send the Proforma Invoice with LEADKIN seal. |
4. Customer arranges the payment for deposit and sends us bank slip. |
5. Middle Production-send photos to show the production line which you can see your products in . Confirm the estimated delivery time again. |
6. End Production-Mass production products photos. |
7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients. |
8. The order is finished perfectly when you receive the goods and get satisfied with them . |
9. Feedback to LEADKIN about quality, service, market feedback & suggestion. And we will do better . |