This is a stainless steel, Type-K Thermocouple Cable . A thermocouple works by taking two wires made of dissimilar metals, connecting them at the two ends, and making a temperature gradient between one end and the other (a 'hot' end and a 'cold' one). Once this is achieved, a voltage potential is formed and current flows. One junction is held in the environment where the temperature of interest exists, this is known as the hot junction. The other junction, referred to as the cold junction, can typically be found in ICs that specialize in reading the temperatures detected by the thermocouple Cable .
This common Type-K Thermocouple is made out of chromel and alumel, while offering a temperature high of 400°C and a low of 0°C.
Quick Details:
Name: Inconel 600 Sheathed Mineral Insulated Cable K Type
Type: K
Conductor material: NiCr-NiSi, NiCrSi-NiSi)
Insulator: 99.6% high purity MgO
Core number: 2
Sheath material: Inconel600
Dia(mm): 0.3mm to 12.7mm
Type for Sheath Wire Type K
Product Name | Code | Type | Shaeth Material | Outside Dia. | Temperature |
NiCr-NiSi /NiCr-NiAl | KK | K | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
SS310 Inconel600 | 0.5-1.0 | 500 | |||
1.5-3.2 | 800 | ||||
4.0-6.4 | 900 | ||||
8.0-12.7 | 1000 | ||||
NiCrSi-NiSi | NK | N | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
SS310 Inconel600 | 0.5-1.0 | 500 | |||
1.5-3.2 | 800 | ||||
4.0-6.4 | 900 | ||||
8.0-12.7 | 1000 | ||||
NiCr-Konstantan | EK | E | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
Fe-Konstantan | JK | J | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
Cu-Konstantan | TK | T | SS304 SS316 | 0.5-1.0 | 400 |
1.5-3.2 | 600 | ||||
4.0-8.0 | 800 | ||||
RhPt10-Ph | SK | S | Inconel600 | 6.0-12.7 | 1100 |
Accuracy for Sheath Wire Type K
Type | Class I | Class II | ||
Accuracy | Temp.Range | Accuracy | Temp.Range | |
K | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-1000℃ | ±0.75% | 375℃-1000℃ | |
N | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-1000℃ | ±0.75% | 375℃-1000℃ | |
E | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-800℃ | ±0.75% | 375℃-800℃ | |
J | ±1.5℃ | -40~375℃ | ±2.5℃ | -40~375℃ |
±0.4% | 375℃-800℃ | ±0.75% | 375℃-800℃ | |
T | ±0.5℃ | -40~125℃ | ±1.0℃ | -40~125℃ |
±0.4% | 125℃-350℃ | ±0.75% | 125℃-350℃ | |
S | 0-1100℃ | ±1.0℃ | 0-1100℃ | ±1.5℃ |
Product Pictures
Company Information:
A. Main Products
B. Package
We add heat shrink tubing and plastic film to make sure high insulated resistance.
Except marking notes, we also have pass card and test report for every coil cable.
C. Warehouse
We have great amount mi cable in stock. We expecting your visiting.
FAQ:
1. Accurate quotation. |
2. Confirm the price, trade term, lead time, payment term etc. |
3. LEADKIN sales send the Proforma Invoice with LEADKIN seal. |
4. Customer arranges the payment for deposit and sends us bank slip. |
5. Middle Production-send photos to show the production line which you can see your products in . Confirm the estimated delivery time again. |
6. End Production-Mass production products photos. |
7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients. |
8. The order is finished perfectly when you receive the goods and get satisfied with them . |
9. Feedback to LEADKIN about quality, service, market feedback & suggestion. And we will do better . |