Features
Specifications
Core: 2,3,4,6
Insulation: MgO
Warranty: 1 Year
Temperature Range: 200℃-1000℃
Accuracy: Class I、II、III
Outside Dia: 0.5-12.7mm
Package: Carton. Pallet
Function: Temperature Test
Cable Length: 1-5m Or Customized
Thermocouple Type: K/N/E/J/T/S/R/B
Highlight:

Mineral insulated thermocouple cable

,

2-6 core MI cable

,

High temperature mineral cable

Basic Infomation
Place of Origin: NINGBO CHINA
Brand Name: LEADKIN
Certification: ISO9001, IATF16949, CE
Model Number: LK-K
Payment & Shipping Terms
Packaging Details: 70*70*8cm Carton
Delivery Time: 2-7 working days
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability: 1,000,000M/year
Product Description
Corrosion-Resistant Mineral Insulated Metal Sheathed Cable for Long-Lasting Performance
Quick Details
  • Type: K/N/E/J/T/S/R/B
  • Place of Origin: Zhejiang, China (Mainland)
  • Accuracy: I-0.4%t, II-0.75%t, III-1.5%t
  • Core number: 2,3,4,6
  • Inorganic mineral insulating lead material: Ni, Cu
  • Insulator: 99.6% high purity MgO
  • Certificate: ISO9001, IATF16949, CE
  • Application: connecting with thermocouple and instrument machine
  • Sheath material: 0Cr18Ni10Ti, SS304S, SS316L, SS316, Cu
  • Sheath Dia(mm): φ3.0, φ4.0, φ6.0, φ8.0
Type for Sheath Wire Type K
Product Name Code Type Sheath Material Outside Dia. Temperature
NiCr-NiSi /NiCr-NiAl KK K SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800

Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples. The data in the table is only recommended data.

Accuracy for Sheath Wire Type K
Type Class I Class II
K ±1.5℃ (-40~375℃) ±2.5℃ (-40~375℃)
±0.4% (375℃-1000℃) ±0.75% (375℃-1000℃)
About this product

Thermocouple Connections: MI cables are commonly used to connect thermocouples to temperature measurement devices in applications such as furnaces, kilns, and chemical processing plants.

Instrumentation: Suitable for connecting various instruments in process control systems, including pressure, flow, and level sensors.

Oil and Gas Industry: Employed in drilling operations, pipelines, and refineries to monitor temperatures in extreme environments.

Power Generation: Used in turbines, boilers, and other critical components where precise temperature measurement is essential for safety and efficiency.

HVAC Systems: Applied in heating, ventilation, and air conditioning systems for accurate temperature monitoring and control.

Installation Considerations
  • Bending Radius: MI cables have a specified minimum bending radius that should be adhered to during installation to avoid damaging the insulation.
  • Termination Techniques: Proper crimping or welding techniques should be used to ensure reliable electrical connections at the thermocouple junctions.
  • Environmental Factors: Consideration of factors such as temperature, pressure, and chemical exposure is critical during the selection and installation of MI cables.
Applications
  • Solid waste incinerators
  • Sintering powdered metals
  • Firing ceramic materials
  • Gas or oil fired furnaces
  • Fuel fired heat exchangers
  • Box furnaces
  • Nuclear or hydrocarbon based energy plants
  • And many more...
Product Pictures
Mineral Insulated Cable 2-6 Core 200℃-1000℃ for Thermocouples 0
Company Information
Main Products
Mineral Insulated Cable 2-6 Core 200℃-1000℃ for Thermocouples 1 Mineral Insulated Cable 2-6 Core 200℃-1000℃ for Thermocouples 2
Package

We add heat shrink tubing and plastic film to make sure high insulated resistance. Except marking notes, we also have pass card and test report for every coil cable.

Mineral Insulated Cable 2-6 Core 200℃-1000℃ for Thermocouples 3
Mi cable Production line

We have high-quality professional products, as well as advanced product lines and equipments. All of the products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world. Along the increasing market demands, we continuously satisfy customers by updating products to improve production systems and quality.

Order Notice
  1. Accurate quotation.
  2. Confirm the price, trade term, lead time, payment term etc.
  3. LEADKIN sales send the Proforma Invoice with LEADKIN seal.
  4. Customer arranges the payment for deposit and sends us bank slip.
  5. Middle Production-send photos to show the production line which you can see your products in. Confirm the estimated delivery time again.
  6. End Production-Mass production products photos.
  7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients.
  8. The order is finished perfectly when you receive the goods and get satisfied with them.
  9. Feedback to LEADKIN about Quality, Service, Market Feedback & Suggestion. And we will do better.
Frequently Asked Questions
What are the advantages of using thermocouples?
  • Wide temperature range
  • Fast response time
  • Simple and rugged design
  • Relatively inexpensive
  • Can be used in various environments, including extreme conditions
What are the disadvantages of thermocouples?
  • Non-linear output, requiring calibration
  • Accuracy may be lower than other temperature sensors (like RTDs)
  • Requires reference junction compensation for precise measurements
  • Susceptible to electromagnetic interference