logo

High Reliability K Type Thermocouple Cable with 200℃-1000℃ Temperature Range, Class I/II/III Accuracy, and MgO Insulation

Basic Properties
Place of Origin: NINGBO CHINA
Brand Name: LEADKIN
Certification: ISO9001, IATF16949, CE
Model Number: LK-K
Trading Properties
Minimum Order Quantity: 50M
Price: negotiation
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability: 1,000,000M/year
Specifications
Brand Name: LEADKIN Core: 2,3,4,6
Insulation: MgO Warranty: 1 Year
Temperature Range: 200℃-1000℃ Accuracy: Class I、II、III
Outside Dia: 0.5-12.7mm Package: Carton. Pallet
Function: Temperature Test Cable Length: 1-5m Or Customized
Certification: ISO9001, IATF16949, CE Thermocouple Type: K/N/E/J/T/S/R/B
High Light:

200℃-1000℃ Temperature Range K Type Thermocouple Cable

,

Class I/II/III Accuracy Thermocouple Extension Cable

,

MgO Insulation Mineral Insulated Thermocouple Cable

Product Description
High Reliability K Type Thermocouple Cable
Ideal for temperature monitoring systems and process control applications in industrial environments.
Product Specifications
  • Type: K/N/E/J/T/S/R/B
  • Place of Origin: Zhejiang, China
  • Accuracy: I-0.4%t, II-0.75%t, III-1.5%t
  • Core Number: 2, 3, 4, 6
  • Lead Material: Ni, Cu
  • Insulator: 99.6% high purity MgO
  • Certifications: ISO9001, IATF16949, CE
  • Application: Connecting with thermocouple and instrument machine
  • Sheath Material: 0Cr18Ni10Ti, SS304S, SS316L, SS316, Cu
  • Sheath Diameter: φ3.0, φ4.0, φ6.0, φ8.0
Sheath Wire Specifications by Type
Product Name Code Type Sheath Material Outside Dia. (mm) Temperature (°C)
NiCr-NiSi /NiCr-NiAlKKKSS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
SS310 Inconel6000.5-1.0500
1.5-3.2800
4.0-6.4900
8.0-12.71000
NiCrSi-NiSiNKNSS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
SS310 Inconel6000.5-1.0500
1.5-3.2800
4.0-6.4900
8.0-12.71000
NiCr-KonstantanEKESS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
Fe-KonstantanJKJSS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
Cu-KonstantanTKTSS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
RhPt10-PhSKSInconel6006.0-12.71100
Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples. The data in the table is recommended data only.
Accuracy Specifications by Type
Type Class I Class II
K±1.5℃ (-40~375℃)
±0.4% (375℃-1000℃)
±2.5℃ (-40~375℃)
±0.75% (375℃-1000℃)
N±1.5℃ (-40~375℃)
±0.4% (375℃-1000℃)
±2.5℃ (-40~375℃)
±0.75% (375℃-1000℃)
E±1.5℃ (-40~375℃)
±0.4% (375℃-800℃)
±2.5℃ (-40~375℃)
±0.75% (375℃-800℃)
J±1.5℃ (-40~375℃)
±0.4% (375℃-800℃)
±2.5℃ (-40~375℃)
±0.75% (375℃-800℃)
T±0.5℃ (-40~125℃)
±0.4% (125℃-350℃)
±1.0℃ (-40~125℃)
±0.75% (125℃-350℃)
S±1.0℃ (0-1100℃)±1.5℃ (0-1100℃)
Product Overview
  • Inorganic mineral insulated cable material is a solid combination of pure nickel/copper wire, inorganic mineral insulation, and metal sleeve, suitable for high temperature environments (200℃~1000℃)
  • Can be used in corrosive environments, flames, metal solutions, and liquid immersion conditions as extension cable
  • Armored thermocouple cable material is a solid composite for manufacturing armored thermocouples
  • Characteristics: Small outer diameter, fast thermal response time, bendable, long service life, excellent airtightness, wide temperature measurement range, and high pressure resistance
  • Applicable temperature range: -200°C to 1300°C (optional)
  • Suitable for various occasions with accuracy grades of 0.4%t and 0.75%t
  • Available in K, N, E, J, T, S, R, B types, can be used in pairs or duplicate
  • Outer sheath diameter ranges from Φ0.5 to Φ12.7 with multiple outer sheath material options
What is a Thermocouple?
A thermocouple is a transducer that converts thermal energy into electrical energy by joining wires of dissimilar metals to create a junction. Temperature changes at this junction generate a measurable voltage used to determine temperature.
Operating on the Seebeck Effect principle, thermocouples generate voltage proportional to temperature changes and the properties of the metals used.
Composed of two insulated wires from different metals connected to a measuring device, thermocouples serve as safety and monitoring tools for various processes and equipment.
Thermocouple assemblies are engineered for harsh, severe, and demanding environments, with selection based on temperature range, ambient atmosphere, media type, required accuracy, and response speed.
Product Images
High Reliability K Type Thermocouple Cable with 200℃-1000℃ Temperature Range, Class I/II/III Accuracy, and MgO Insulation 0
Company Information
Main Products: Professional thermocouple cables and industrial temperature measurement solutions
High Reliability K Type Thermocouple Cable with 200℃-1000℃ Temperature Range, Class I/II/III Accuracy, and MgO Insulation 1 High Reliability K Type Thermocouple Cable with 200℃-1000℃ Temperature Range, Class I/II/III Accuracy, and MgO Insulation 2
Packaging
We add heat shrink tubing and plastic film to ensure high insulated resistance. Each coil cable includes marking notes, pass card, and test report.
High Reliability K Type Thermocouple Cable with 200℃-1000℃ Temperature Range, Class I/II/III Accuracy, and MgO Insulation 3
Production Capabilities
We maintain high-quality professional products with advanced production lines and equipment. All products comply with international quality standards and are appreciated in global markets. We continuously update products and improve production systems to meet increasing market demands.
Ordering Process
  1. Accurate quotation provided
  2. Confirmation of price, trade terms, lead time, payment terms
  3. LEADKIN sales sends Proforma Invoice with company seal
  4. Customer arranges deposit payment and provides bank slip
  5. Production updates with photos showing your products in production line
  6. Mass production completion with product photos
  7. Client makes balance payment and LEADKIN ships goods
  8. Tracking number provided and shipment status monitored
  9. Order completion when goods are received and customer satisfaction confirmed
  10. Feedback on quality, service, and market performance for continuous improvement